Heat Loss of a Home: Boiler and Radiator Power
Last updated: · 2 min read
Sizing heating by floor area alone over- or undershoots. The tool multiplies wall, window, roof and floor area by U-value, adds air change and gives the total in kW and kcal/h, item by item. This guide explains the formula, works through an example and lists the usual mistakes.
Formula
Transmission = U × A × ΔT Ventilation = 0.33 × n × V × ΔT Total = transmission + ventilation
0.33 is the volumetric heat capacity of air (Wh/m³K); ΔT is indoor minus outdoor design temperature.
What the inputs mean
- Walls (area)
- Outer wall area.
- Walls (U)
- Wall U-value, 0.3–0.6 when insulated.
- Windows and doors (area)
- Window and door area.
- Windows and doors (U)
- U-value of glazing and frame.
- Heated volume
- Heated volume.
- Air changes per hour
- Air changes per hour.
- Indoor temperature
- Indoor temperature.
- Outdoor design temperature
- Outdoor design temperature.
Worked example: 80 m² home, outdoors −3 °C, indoors 20 °C
- Walls 690 W, windows 621 W, roof 736 W, floor 920 W.
- Ventilation: 0.33 × 0.7 × 200 × 23 = 1,062.6 W.
- Total 4.03 kW; 3,464.83 kcal/h.
Result: Heating power should be at least 4.03 kW.
Also in this calculator
- Compare: up to three results side by side, with differences in amount and percent
- Chart: how the result moves when one value changes
- Solve backwards: type the result you want and find the value you need
- Download Excel: inputs, result and the table if there is one
- Save: keep the calculation in your own browser only
How to read the result
For preliminary sizing only; a qualified engineer must check the design and protection. Thermal bridges and solar gains are excluded; use EN 12831 for design.
Common mistakes
- Entering λ instead of U.
- Not subtracting windows from walls.
- Using today's temperature instead of the design value.
Frequently asked questions
Where do I find U-values?
On the window label or in building codes.
kcal/h and kW?
1 kW = 859.8 kcal/h.
Choosing radiators?
Calculate each room; this is the whole building.